GOSSEN PROFISIX MANUAL PDF

GOSSEN PROFISIX MANUAL PDF

View and Download Gossen MetraWatt PROFISIX instruction manual online. hand-held exposure meter. PROFISIX Measuring Instruments pdf manual. You have an older device from GOSSEN? Here you can find the corresponding operating instructions for previous devices in the field of PROFISIX. Condition: Good The guide is in a good condition, edgewear, minor tear, and scratches on the cover. The inside leaves.

Author: Tygojar Nikasa
Country: Uganda
Language: English (Spanish)
Genre: Travel
Published (Last): 24 February 2009
Pages: 211
PDF File Size: 9.35 Mb
ePub File Size: 13.19 Mb
ISBN: 978-9-13524-316-2
Downloads: 17538
Price: Free* [*Free Regsitration Required]
Uploader: Faejin

Write a customer review. In the mean-time I have an interesting read about incident meters in BTZS book in measuring the scene brightness range. One would expect it to be off in all but one at least type of reading if it is a faulty meter. Personally, I like the user interface of the older Luna Pro, where I can take the reading first, and then set the dial.

Gossen MetraWatt PROFISIX Instruction Manual

Whatever it is, I must say that I prefer the added precision this has given. Interesting the comment above to this effect too. Recently I have been taking the leather cover away as it seems to reduce the size enough to make it comfortable.

I have never seen or heard of a Profisix that behaves like yours, Jesper. Does that also prove the same point, or a different one?

East Dane Designer Men’s Fashion. If you are a seller for this product, would you like to suggest updates through seller support? Only negative msnual it’s size. If however there is a difference between the currents, this difference will be seen as a current running through the spool, generating a magnetic field that moves the needle accordingly. The current generated by the lrofisix light is balanced against another running through the amplifier.

  GIOVANNI SARTORI LA SOCIEDAD TELEDIRIGIDA PDF

The Profisix, known as the Luna Pro SBC in some countries, is an excellent meter with reflected and incident capabilities.

Last edited by a moderator: Sorry Jasper but you are quite wrong the numbers either side of the 0 used for the null reading are whole stops, and clearly marked as such in the meter’s handbook. I do, by the way not only use the null position. Discussion in ‘ Lighting ‘ started by JmqxAug 22, Together with the adapters the Profisix forms a complete light measurement system. Adapters Size Weight Power Manual. Now, I would like to get this meter but there are mwnual concerns like the age, reliability and battery it takes.

This however relies on the precision of the original measurement like enlarging a photo.

Gossen Profisix Original Instruction Manual: : Books

It uses the extremely common 9 volt battery. Some 10 different adapters are available for a broad range of applications like the Tele adapter, reproduction adapter, LAB adapter for darkroom appl.

One easy check is to take one reading, move the needle to 3 and you will see that you have moved 1 stop and not 3. The Profisix and Lunapro does not work in the same way. But on the other hand, if this is some kind of adjustment then there should be others with the same kind of meter.

However, should I then not be able to vary f-stop and shutter speeds and receive corresponding movements on the needle as to the exposure – such as can be done on the camera itself?

Withoutabox Submit to Film Festivals.

Gossen Profisix -or- new light meter.

Example of complete set. I wish there would be this device but in the same size as the smallest possible meters. Would you like to tell us about a lower price? Discover Prime Book Box for Kids. I could post a film of the way my profiwix works, but I would have to get some kind of digital camera first. The computer dial incorporates standard exposure compensation, exposure factor compensation manula filters or close up work, as well as I – IX steps for zone exposure.

  C5200 DATASHEET PDF

Do you already have an account? More detailed ogssen about the attachments can be found on the attachments page. Following the instructions to take an incident reading I set ASA speed, then point and take a reading, then turn the outside dial to match the exposure needle to the correct exposure. Learn more about Amazon Prime. It takes the 9v rectangular battery. Explore the Home Gift Guide.

It has further reduced sensitivity and does not provide flash metering. Amazon Inspire Digital Educational Resources. I’ve only had mine for 10 years profiskx it has worked flawlessly all the time.

But they fit your hand so gracefully, one-handed operation is a treat. Amazon Advertising Find, attract, and engage customers.

I use mine daily, and I think that I’ve had the same battery in the meter for 10 years now. Any of these chunky Gossen meters take a lot of room in your pocket. Adjust the ratio and you have adjusted the movement. This scenario is not very likely.