of Petroleum and Petroleum Products (ASTM Practice. D ). MPMS Chapter Determination of Water in Crude Oil by the Distillation Method (ASTM Test. ASTM D Standard Test Method for WATER IN PETROLEUM PRODUCTS AND BITUMINOUS MATERIALS BY DISTILLATION. ASTM D Standard Test Method for Water in Petroleum Products and Bituminous Materials by Distillation.

Author: Akikinos Sagami
Country: Belgium
Language: English (Spanish)
Genre: Medical
Published (Last): 21 March 2012
Pages: 209
PDF File Size: 8.90 Mb
ePub File Size: 5.24 Mb
ISBN: 678-6-99217-936-2
Downloads: 11351
Price: Free* [*Free Regsitration Required]
Uploader: Kazikazahn

With both types of volumetric KF, imidazole is the base used most frequently as a buffer to maintain optimal pH for the reaction. The gas ring burner shall be of such dimensions that it may be moved up and down the vessel when testing materials that are likely to foam or solidify in the still.

However, due to solubility and reactivity issues described above, analysts often drastically reduce sample size, which tends to reduce the reproducibility of test results.

In coulometry, the quantity of iodine generated corresponding to the amount of water present is calculated by the titrator on the basis of current mA and time sec.

Distillation ml Flask Heater Part Number The Seta Distillation Flask Heater is a regulated heating mantel which has the capacity to accommodate a ml flask. NOTE 1—Volatile water-soluble material, if present, may be measured as water.

ASTM D95 distillation method portable transformer oil moisture analyzer. It is a general purpose heating mantel designed for laboratory procedures that require precise temperature control.

Product Uses Petroleum moisture tester: Summary of Test Method 4. In one-component KF, the titrant usually referred to as a CombiTitrant or a composite contains all the ingredients needed for the KF reaction, namely iodine, sulfur dioxide, base and a suitable alcohol, while the solvent is typically dry methanol.

Note; clamp, bosshead and glassware available separately See detailed specifications Available accessories Request a quotation More products in this subcategory. The condenser tube and trap must be chemically clean to ensure free drainage of water into the bottom of the trap.

Astm D95, Astm D95 Suppliers and Manufacturers at

Coulometric KF is most accurate in the range of 1 ppm to 5 percent water. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend. HZWS-2 astm d95 petroleum products karl fischer trace water tester. KF analysis is a versatile and robust analytical tool for water content analysis in oil samples, and can detect water in any of three states commonly found in oils.

  BLOODSUCKING FIENDS CHRISTOPHER MOORE PDF

As a guideline, sample sizes shown in Table 1 are recommended for volumetric and coulometric KF, respectively. The Best Gets Better: In two-component KF, the titrant contains only an alcoholic solution of iodine, while the solvent contains the other ingredients needed for the reaction. A wide variety of astm d95 options are available to you, such as paid samples. The two types of volumetric KF differ in the exact composition of titrant and solvent.

ASTM D Water in Petroleum Products & Bituminous Materials by Dist_

Copyright Stanhope—Seta Limited Strategies for Removing Water from Oil. Methods of test for petroleum and its products. Rinse the material adhering to the cylinder with one mL and two mL portions of the astmm liquid see Section 6 and Table 1.

If the metal still is used, start heating with the ring burner about 76 mm 3 in. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility. The precision when using the 2-mL trap or a 5—mL trap has not been established. It is estimated that nearlyKF determinations are performed daily around the world. Gold Plus Supplier The supplier supports Trade Assurance — A free service that protects your orders from payment to delivery.

Petroleum products and bituminous materials. Drain the cylinder thoroughly after the sample transfer and each rinsing.

You can ensure product safety by selecting from certified suppliers, including 42 asym Other, 24 with ISO certification. Vessels of, and mL nominal capacity have proved astmm. How is the technical services on the product9 Engineer available to awtm machinery overseas. Asphalt moisture is water quantity of the asphalt sample, expressed by quality percentage.

Standard test method for water in petroleum products and bituminous materials by distillation. Create your own user feedback survey. Key Components of a Modern Volumetric KF Titrator Coulometric KF In coulometric KF, the iodine needed by the KF reaction is not present v95 the KF reagent, but is instead generated electrochemically in situ from iodide at the anode of the generator electrode, a component of the coulometric titration cell Figure 2.

  AADMER AGREEMENT PDF

NOTE 3—Instead of standardizing on a particular apparatus speci? In other words, the larger the sample, the less error is introduced into e95 analysis by sample weighing, transfer and other handling. About product and suppliers: Sample Size and Reproducibility As with adtm analytical technique, the sampling error in KF analysis is inversely proportional to the sample size.

D95 — 05 4. The heating element is made of glass fibre which minimises damage to the flask in case of a slight impact between flask and heater.

That is, while the iodine in the KF reagent is reacting with water, there is no free iodine present in the titration cell, and a high voltage is required to maintain the set polarization current at the double platinum pin indicator electrode.

High water content of lubricating oils negatively impacts the operation and longevity of the oils and the mechanical equipment components being lubricated. D95 — 05 the case of Style E; 0. The still, trap, and condenser may be connected by any suitable method that produces a leakproof joint. Procedure NOTE 4—The precision of this test method will be affected by water droplets adhering to surfaces in the apparatus and therefore not settling into the water trap to be measured. The following reactions represent this two-step mechanism.

Distillation 1000ml Flask Heater

Zstm have ashm months warranty, if it broken during transport, we can change a new one for you. Permission rights to photocopy the standard may also be secured from the ASTM website www. Finding the Source of Water Contamination in Oil. Once all the water has reacted with the iodine, trace quantities of free iodine appear in the titration cell, causing a drop in voltage necessary to keep the polarization current constant, which in turn signals the end-point of the titration.